SP7015 TRX MACHINE MAINTENANCE
26
Always clean tip of grease gun fitting and grease fitting on machine before attaching hose
to prevent dirt from being forced into machine parts.
• Grease the bearing supported stub shaft every
1000 hours of operation using Texaco® Starplex
II grease. The grease fitting is easily accessible
behind the V-belt guard. Apply grease using a
hand held grease gun until the pin extends from
the pressure relief valve (located 180°from
grease fitting on the bearing). Wipe off excess
grease. Excess grease will attract dirt.
• A grease fitting is on the end of the stub shaft to
grease the spline coupling. Apply 2 to 3 shots
of grease approximately every 1000 hours of
operation. Wipe off excess grease. Excess
grease will attract dirt. DO NOT over
grease, over greasing could cause a hydraulic
type lift on seals.
GREASE APPROXIMATELY EVERY 1000
HOURS OF OPERATION
PIN
Comments to this Manuals